  • Belimo C220Q-K Zone valve (2-way)

    Belimo C220Q-K Zone valve (2-way)

    The C220Q-K Zone valve is 2-way, DN 15, Internal thread, Rp 1/2", PN 25, ps 1600 kPa, Kvs 4.8 m³/h, Fluid temperature 2...100°C [36...212°F] (with actuator 2...90°C) Click here for the technical data PDF The Belimo C220Q-K 2-way zone valve are expertly designed for closed cold and warm water systems. Ideal for shut-off functions and modulating controls on the water side of air-handling units and heating systems, this series offers reliable performance and ease of use. With snap-assembly actuators and a range of technical specifications, these valves ensure efficient and precise fluid flow control. Functional Data Fluid Compatibility: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature Range: 2...100°C (with actuator 2...90°C) Close-off Pressure (∆ps): 520 kPa Differential Pressure (Δpmax): 280 kPa Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° (Operating range 15...90°) Installation Orientation: Upright to horizontal   Mechanical Data Valve Body Material: Brass Closing Element: Chrome-plated brass Spindle: Brass Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM Pipe Connection: Internal thread according to ISO 7-1   Snap-Assembly Actuator: Tool-free snap assembly for quick and easy installation. Flow Setting: Adjustable angle of rotation in 2.5° increments for precise flow control. Maintenance-Free: Both ball valves and rotary actuators require no maintenance. Flow Direction: Bidirectional flow capability.   Accessories Spindle Extension (CQ ZCQ-E) Pipe Connectors:   DN 15 Rp 1/2" (ZR2315)   DN 20 Rp 3/4" (ZR2320)   DN 25 Rp 1" (ZR2325)   Installation Notes Permissible Orientation: Must not be installed in a hanging position. Water Quality Requirements: Adherence to VDI 2035 for long-term functionality. Servicing: Isolate the rotary actuator from the power supply before any service work. Ensure all components are cooled down, and system pressure is reduced to ambient level.   Certification and Compliance Safety: Designed for stationary heating, ventilation, and air-conditioning systems. EMC and Certification: Conforms to relevant standards, ensuring safe and reliable operation. Belimo's C220Q-K zone valve offers superior control and reliability for your HVAC systems. With a focus on ease of installation, maintenance-free operation, and precision control, these valves are the ideal choice for professional tradesmen and engineering companies.   For more information and to explore our range of Belimo products, visit our website at (https://ecospares.co.uk/collections/belimo. If you need any assistance, please get in touch with us on 01772 284 626.

    £42.20£29.54

  • Belimo C215Q-J Zone valve (2-way)

    Belimo C215Q-J Zone valve (2-way)

    Zone valve, 2-way, DN 15, Internal thread, Rp 1/2", PN 25, ps 1600 kPa, Kvs 4.8 m³/h, Fluid temperature 2...100°C [36...212°F] (with actuator 2...90°C) Click here for the technical data PDF The Belimo C215Q-J 2-way zone valve are expertly designed for closed cold and warm water systems. Ideal for shut-off functions and modulating controls on the water side of air-handling units and heating systems, this series offers reliable performance and ease of use. With snap-assembly actuators and a range of technical specifications, these valves ensure efficient and precise fluid flow control. Functional Data Fluid Compatibility: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature Range: 2...100°C (with actuator 2...90°C) Close-off Pressure (∆ps): 520 kPa Differential Pressure (Δpmax): 280 kPa Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° (Operating range 15...90°) Installation Orientation: Upright to horizontal   Mechanical Data Valve Body Material: Brass Closing Element: Chrome-plated brass Spindle: Brass Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM Pipe Connection: Internal thread according to ISO 7-1   Snap-Assembly Actuator: Tool-free snap assembly for quick and easy installation. Flow Setting: Adjustable angle of rotation in 2.5° increments for precise flow control. Maintenance-Free: Both ball valves and rotary actuators require no maintenance. Flow Direction: Bidirectional flow capability.   Accessories Spindle Extension (CQ ZCQ-E) Pipe Connectors:   DN 15 Rp 1/2" (ZR2315)   DN 20 Rp 3/4" (ZR2320)   DN 25 Rp 1" (ZR2325)   Installation Notes Permissible Orientation: Must not be installed in a hanging position. Water Quality Requirements: Adherence to VDI 2035 for long-term functionality. Servicing: Isolate the rotary actuator from the power supply before any service work. Ensure all components are cooled down, and system pressure is reduced to ambient level.   Certification and Compliance Safety: Designed for stationary heating, ventilation, and air-conditioning systems. EMC and Certification: Conforms to relevant standards, ensuring safe and reliable operation. Belimo's C215Q-J zone valve offers superior control and reliability for your HVAC systems. With a focus on ease of installation, maintenance-free operation, and precision control, these valves are the ideal choice for professional tradesmen and engineering companies.   For more information and to explore our range of Belimo products, visit our website at (https://ecospares.co.uk/collections/belimo. If you need any assistance, please get in touch with us on 01772 284 626.

    £35.00£24.50

  • Belimo R3032-S3 Ball Valve (3-Way) (DN32)

    Belimo R3032-S3 Ball Valve (3-Way) (DN32)

    The Belimo R3032-S3 3-Way Ball Valve is a versatile and reliable solution for precise fluid control in industrial applications. Designed with three ports for directional flow control, it offers minimal pressure drops, quick responsiveness, and impressive sealing capabilities. This valve is ideal for mixing or diverting fluids, making it suitable for chemical processing, water treatment, and food and beverage industries. Its robust construction ensures durability and safety in harsh environments. The electrical automation of the valve enhances operational efficiency with remote monitoring and control. Choose the Belimo R3032-S3 for dependable performance and seamless integration with industrial control systems.   Click here for the technical data PDF    Functional Data - Fluid: Cold and warm water, water with glycol up to max. 50% vol. - Fluid Temperature: -10...120°C [14...248°F]        - Note: At a fluid temperature of -10...2°C, a spindle heater or a valve neck extension is recommended. The allowed fluid temperature can be limited depending on the type of actuator. Limitations can be found in the actuators' respective data sheets. - Close-off Pressure: 1400 kPa - Differential Pressure Δpmax: 1000 kPa   - Note: 200 kPa for low-noise operation - Flow Bypass B – AB: Approx. 50% of Kvs value - Leakage Rate:   - Port A – AB: Air-bubble tight, leakage rate A (EN 12266-1)   - Bypass B – AB: Leakage class I (EN 1349 and EN 60534-4), max. 1% of the Kvs value - Angle of Rotation: 90° - Pipe Connection: Internal thread according to ISO 7-1 - Installation Orientation: Upright to horizontal (in relation to the stem) - Servicing: Maintenance-free - Air-bubble tight (control path A – AB)    Materials - Valve Body: Nickel-plated brass body - Body Finish: Nickel-plated - Closing Element: Stainless steel - Spindle: Stainless steel - Spindle Seal: EPDM O-ring        Electrical Accessories - Stem Heater DN 15...50 (20 W): ZR24-2    Mechanical Accessories - Valve Neck Extension for Ball Valve DN 15...50: ZR-EXT-01 - Pipe Connectors:   - DN 15 Rp 1/2": ZR2315   - DN 20 Rp 3/4": ZR2320   - DN 25 Rp 1": ZR2325   - DN 32 Rp 1 1/4": ZR2332   - DN 40 Rp 1 1/2": ZR2340   - DN 50 Rp 2": ZR2350        Installation Notes   - Permissible Installation Orientation: The ball valve can be installed upright to horizontal. It may not be installed in a hanging position (spindle pointing downwards). - Water Quality Requirements: Must adhere to VDI 2035 specifications. To ensure long-term functionality, valves must be kept free from particle debris. Installing a suitable strainer is recommended. - Servicing: Maintenance-free ball valves and rotary actuators. Isolate the rotary actuator from the power supply before service work. Switch off pumps in the piping system, close slide valves, and reduce system pressure to ambient levels. Return the system to service only after proper reassembly and refilling by trained personnel. - Flow Direction: Comply with the specified direction of flow indicated by an arrow on the housing to prevent valve damage. Ensure the ball is correctly positioned (marking on the spindle).     Our website offers all Belimo products. For more information and to explore our range, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £248.00£173.60

  • Belimo R3032-16-S3 Ball Valve (3-Way) (DN32)

    Belimo R3032-16-S3 Ball Valve (3-Way) (DN32)

    The Belimo R3032-16-S3 3-Way Ball Valve is a versatile and reliable solution for precise fluid control in industrial applications. Designed with three ports for directional flow control, it offers minimal pressure drops, quick responsiveness, and impressive sealing capabilities. This valve is ideal for mixing or diverting fluids, making it suitable for chemical processing, water treatment, and food and beverage industries. Its robust construction ensures durability and safety in harsh environments. The electrical automation of the valve enhances operational efficiency with remote monitoring and control. Choose the Belimo R3032-16-S3 for dependable performance and seamless integration with industrial control systems.   Click here for the technical data PDF    Functional Data - Fluid: Cold and warm water, water with glycol up to max. 50% vol. - Fluid Temperature: -10...120°C [14...248°F]        - Note: At a fluid temperature of -10...2°C, a spindle heater or a valve neck extension is recommended. The allowed fluid temperature can be limited depending on the type of actuator. Limitations can be found in the actuators' respective data sheets. - Close-off Pressure: 1400 kPa - Differential Pressure Δpmax: 1000 kPa   - Note: 200 kPa for low-noise operation - Flow Bypass B – AB: Approx. 50% of Kvs value - Leakage Rate:   - Port A – AB: Air-bubble tight, leakage rate A (EN 12266-1)   - Bypass B – AB: Leakage class I (EN 1349 and EN 60534-4), max. 1% of the Kvs value - Angle of Rotation: 90° - Pipe Connection: Internal thread according to ISO 7-1 - Installation Orientation: Upright to horizontal (in relation to the stem) - Servicing: Maintenance-free - Air-bubble tight (control path A – AB)    Materials - Valve Body: Nickel-plated brass body - Body Finish: Nickel-plated - Closing Element: Stainless steel - Spindle: Stainless steel - Spindle Seal: EPDM O-ring        Electrical Accessories - Stem Heater DN 15...50 (20 W): ZR24-2    Mechanical Accessories - Valve Neck Extension for Ball Valve DN 15...50: ZR-EXT-01 - Pipe Connectors:   - DN 15 Rp 1/2": ZR2315   - DN 20 Rp 3/4": ZR2320   - DN 25 Rp 1": ZR2325   - DN 32 Rp 1 1/4": ZR2332   - DN 40 Rp 1 1/2": ZR2340   - DN 50 Rp 2": ZR2350        Installation Notes   - Permissible Installation Orientation: The ball valve can be installed upright to horizontal. It may not be installed in a hanging position (spindle pointing downwards). - Water Quality Requirements: Must adhere to VDI 2035 specifications. To ensure long-term functionality, valves must be kept free from particle debris. Installing a suitable strainer is recommended. - Servicing: Maintenance-free ball valves and rotary actuators. Isolate the rotary actuator from the power supply before service work. Switch off pumps in the piping system, close slide valves, and reduce system pressure to ambient levels. Return the system to service only after proper reassembly and refilling by trained personnel. - Flow Direction: Comply with the specified direction of flow indicated by an arrow on the housing to prevent valve damage. Ensure the ball is correctly positioned (marking on the spindle).     Our website offers all Belimo products. For more information and to explore our range, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £257.00£179.90

  • Belimo R3025-S2 Ball Valve (3-Way) (DN25)

    Belimo R3025-S2 Ball Valve (3-Way) (DN25)

    For Closed Cold and Warm Water Systems, this is Ideal for switching functions and 2-point controls on the water side of air-handling units and heating systems.    Click here for the technical data PDF    Functional Data - Fluid: Cold and warm water, water with glycol up to max. 50% vol. - Fluid Temperature: -10...120°C [14...248°F]        - Note: At a fluid temperature of -10...2°C, a spindle heater or a valve neck extension is recommended. The allowed fluid temperature can be limited depending on the type of actuator. Limitations can be found in the actuators' respective data sheets. - Close-off Pressure: 1400 kPa - Differential Pressure Δpmax: 1000 kPa   - Note: 200 kPa for low-noise operation - Flow Bypass B – AB: Approx. 50% of Kvs value - Leakage Rate:   - Port A – AB: Air-bubble tight, leakage rate A (EN 12266-1)   - Bypass B – AB: Leakage class I (EN 1349 and EN 60534-4), max. 1% of the Kvs value - Angle of Rotation: 90° - Pipe Connection: Internal thread according to ISO 7-1 - Installation Orientation: Upright to horizontal (in relation to the stem) - Servicing: Maintenance-free - Air-bubble tight (control path A – AB)    Materials - Valve Body: Nickel-plated brass body - Body Finish: Nickel-plated - Closing Element: Stainless steel - Spindle: Stainless steel - Spindle Seal: EPDM O-ring        Electrical Accessories - Stem Heater DN 15...50 (20 W): ZR24-2    Mechanical Accessories - Valve Neck Extension for Ball Valve DN 15...50: ZR-EXT-01 - Pipe Connectors:   - DN 15 Rp 1/2": ZR2315   - DN 20 Rp 3/4": ZR2320   - DN 25 Rp 1": ZR2325   - DN 32 Rp 1 1/4": ZR2332   - DN 40 Rp 1 1/2": ZR2340   - DN 50 Rp 2": ZR2350        Installation Notes   - Permissible Installation Orientation: The ball valve can be installed upright to horizontal. It may not be installed in a hanging position (spindle pointing downwards). - Water Quality Requirements: Must adhere to VDI 2035 specifications. To ensure long-term functionality, valves must be kept free from particle debris. Installing a suitable strainer is recommended. - Servicing: Maintenance-free ball valves and rotary actuators. Isolate the rotary actuator from the power supply before service work. Switch off pumps in the piping system, close slide valves, and ensure system pressure is reduced to ambient levels. Return the system to service only after proper reassembly and refilling by trained personnel. - Flow Direction: Comply with the specified direction of flow indicated by an arrow on the housing to prevent valve damage. Ensure the ball is correctly positioned (marking on the spindle).         Our website offers all Belimo products. For more information and to explore our range, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £171.00£119.70

  • Belimo R3025-10-S2 (3-Way) Control Valve

    Belimo R3025-10-S2 (3-Way) Control Valve

      This Belimo 3-Way Characterised Control Valve is designed for closed cold and warm water systems. It is ideal for modulating control of air-handling and heating systems on the water side, ensuring efficient and precise flow regulation.   Click here for the technical data PDF   Type Overview    - R3025-10-S2   - DN25    - RP 1"   - 10m³/h   -  PN40   - 3.2n(gl)   - 100 Sv min.     Functional Data:   - Fluid: Cold and warm water, water with glycol up to 50% vol.   - Fluid Temperature: -10°C to 120°C [14°F to 248°F]   - Close-off Pressure: 1400 kPa   - Differential Pressure (Δpmax): 350 kPa   - Flow Characteristics:     - Control Path A – AB: Equal percentage (VDI/VDE 2173)     - Bypass B – AB: Linear (VDI/VDE 2173)   - Leakage Rate:     - Control Path A – AB: Air-bubble tight, leakage rate A (EN 12266-1)     - Bypass B – AB: Leakage class I (EN 1349 and EN 60534-4) 1-2% of Kvs value   Mechanical Data:   - Valve Body: Nickel-plated brass   - Closing Element: Stainless steel   - Spindle: Stainless steel   - Spindle Seal: EPDM O-ring   - Seat: PTFE, O-ring EPDM   - Characterised Disc: ETFE (DN 15, 20, 25, 32, 40, 50) or stainless steel (DN 40, 50)   Operational Data:   - Angle of Rotation: 90° (Control path A – AB: 15-90°, Bypass B – AB: 15-70°)   - Pipe Connection: Internal thread (ISO 7-1)   - Installation Orientation: Upright to horizontal   - Servicing: Maintenance-free   Accessories: - Electrical:   - Stem heater DN 15-50 (20 W) ZR24-2 - Mechanical:   - Valve neck extension for ball valve DN 15-50 ZR-EXT-01   - Pipe connectors for ball valves (various sizes)   Installation Notes: - The ball valve can be installed upright to horizontal but not in a hanging position. - Water quality must meet VDI 2035 standards. Installation of a suitable strainer is recommended. - Ensure the correct flow direction as specified by the housing arrow.   Why You Should Buy: Efficiency: Ensures precise flow control for optimal heating and air-handling performance. Durability: Made with high-quality materials for long-term use. Versatility: Suitable for a variety of closed water systems.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please get in touch with us on 01772 284 626.  

    £182.00£127.40

  • Belimo R2050-S4 Open/Close 2-Way Ball Valve

    Belimo R2050-S4 Open/Close 2-Way Ball Valve

    For tradesmen and engineering companies seeking reliable and efficient components for their water systems, the Belimo Open/Close Ball Valve R2050-S4 is an excellent choice. These valves are designed for heating, ventilation, and air-conditioning systems and ensure optimal performance and longevity. Click here for the technical data PDF The Belimo R2050-S4 series valves are designed for open and closed cold and warm water systems. They are ideal for shut-off functions in water systems and provide 2-point controls in air-handling units and heating systems. These valves are air-bubble tight, ensuring no leakage and maintaining system integrity.   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -10°C to 120°C (14°F to 248°F) Note: At fluid temperatures of -10°C to 2°C, a spindle heater or valve neck extension is recommended. The allowed fluid temperature may be limited based on the type of actuator used. Close-off Pressure (Δps): 1400 kPa Differential Pressure (Δpmax): 1000 kPa (200 kPa for low-noise operation) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal (relative to the stem) Servicing: Maintenance-free   Materials: Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Operating Mode: The open/close ball valve is adjusted by a rotary actuator, connected by an open/close signal. Turn the valve counterclockwise to open and clockwise to close. Flow Direction: The direction of flow is indicated by an arrow on the housing, ensuring correct installation and preventing damage. Permissible Installation Orientation: Upright to horizontal. Avoid hanging position (spindle pointing downwards).   Electrical Accessories: Stem heater DN 15...50 (20 W) Type: ZR24-2 Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 Type: ZR-EXT-01   Pipe connectors for ball valve with internal thread:     DN 15 Rp 1/2" Type: ZR2315     DN 20 Rp 3/4" Type: ZR2320     DN 25 Rp 1" Type: ZR2325     DN 32 Rp 1 1/4" Type: ZR2332     DN 40 Rp 1 1/2" Type: ZR2340     DN 50 Rp 2" Type: ZR2350   Why You Should Buy High Performance: With high close-off and differential pressures, these valves ensure reliable operation even under demanding conditions. Durability: Constructed with nickel-plated brass and stainless steel, these valves offer long-term durability and resistance to wear and corrosion. Ease of Installation and Maintenance: Featuring a simple design with internal threading, these valves are easy to install and require no maintenance, ensuring hassle-free operation. Comprehensive Accessories: A range of accessories is available to enhance functionality and adapt the valve to specific requirements.   Additional Notes Water Quality Requirements: Adhere to VDI 2035 water quality requirements. A suitable strainer should be installed to keep the valves free from particle debris. Servicing: Ensure all electrical connections are isolated and the system is depressurized before servicing.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £227.00£158.90

  • Belimo R2040-S3 Open/Close 2-Way Ball Valve

    Belimo R2040-S3 Open/Close 2-Way Ball Valve

    Open/close ball valve, 2-way, DN 40, Internal thread, Rp 1 1/2", PN 25, ps 1600 kPa, Kvs 31 m³/h, Fluid temperature -10...120°C [14...248°F] Click here for the technical data PDF For tradesmen and engineering companies seeking reliable and efficient components for their water systems, the Belimo Open/Close Ball Valve R2040-S3 is an excellent choice. These valves are designed for heating, ventilation, and air-conditioning systems and ensure optimal performance and longevity. The Belimo R2040-S3 series valves are designed for open and closed cold and warm water systems. They are ideal for shut-off functions in water systems and provide 2-point controls in air-handling units and heating systems. These valves are air-bubble tight, ensuring no leakage and maintaining system integrity.   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -10°C to 120°C (14°F to 248°F) Note: At fluid temperatures of -10°C to 2°C, a spindle heater or valve neck extension is recommended. The allowed fluid temperature may be limited based on the type of actuator used. Close-off Pressure (Δps): 1400 kPa Differential Pressure (Δpmax): 1000 kPa (200 kPa for low-noise operation) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal (relative to the stem) Servicing: Maintenance-free   Materials: Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Operating Mode: The open/close ball valve is adjusted by a rotary actuator, connected by an open/close signal. Turn the valve counterclockwise to open and clockwise to close. Flow Direction: The direction of flow is indicated by an arrow on the housing, ensuring correct installation and preventing damage. Permissible Installation Orientation: Upright to horizontal. Avoid hanging position (spindle pointing downwards).   Electrical Accessories: Stem heater DN 15...50 (20 W) Type: ZR24-2 Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 Type: ZR-EXT-01   Pipe connectors for ball valve with internal thread:     DN 15 Rp 1/2" Type: ZR2315     DN 20 Rp 3/4" Type: ZR2320     DN 25 Rp 1" Type: ZR2325     DN 32 Rp 1 1/4" Type: ZR2332     DN 40 Rp 1 1/2" Type: ZR2340     DN 50 Rp 2" Type: ZR2350   Why You Should Buy High Performance: With high close-off and differential pressures, these valves ensure reliable operation even under demanding conditions. Durability: Constructed with nickel-plated brass and stainless steel, these valves offer long-term durability and resistance to wear and corrosion. Ease of Installation and Maintenance: Featuring a simple design with internal threading, these valves are easy to install and require no maintenance, ensuring hassle-free operation. Comprehensive Accessories: A range of accessories is available to enhance functionality and adapt the valve to specific requirements.   Additional Notes Water Quality Requirements: Adhere to VDI 2035 water quality requirements. A suitable strainer should be installed to keep the valves free from particle debris. Servicing: Ensure all electrical connections are isolated and the system is depressurized before servicing.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £172.00£120.40

  • Belimo R2032-S3 Open/Close 2-Way Ball Valve

    Belimo R2032-S3 Open/Close 2-Way Ball Valve

    For tradesmen and engineering companies seeking reliable and efficient components for their water systems, the Belimo Open/Close Ball Valve R2032-S3 is an excellent choice. These valves are designed for heating, ventilation, and air-conditioning systems and ensure optimal performance and longevity. Click here for the technical data PDF The Belimo R2032-S3 series valves are designed for open and closed cold and warm water systems. They are ideal for shut-off functions in water systems and provide 2-point controls in air-handling units and heating systems. These valves are air-bubble tight, ensuring no leakage and maintaining system integrity.   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -10°C to 120°C (14°F to 248°F) Note: At fluid temperatures of -10°C to 2°C, a spindle heater or valve neck extension is recommended. The allowed fluid temperature may be limited based on the type of actuator used. Close-off Pressure (Δps): 1400 kPa Differential Pressure (Δpmax): 1000 kPa (200 kPa for low-noise operation) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal (relative to the stem) Servicing: Maintenance-free   Materials: Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Operating Mode: The open/close ball valve is adjusted by a rotary actuator, connected by an open/close signal. Turn the valve counterclockwise to open and clockwise to close. Flow Direction: The direction of flow is indicated by an arrow on the housing, ensuring correct installation and preventing damage. Permissible Installation Orientation: Upright to horizontal. Avoid hanging position (spindle pointing downwards).   Electrical Accessories: Stem heater DN 15...50 (20 W) Type: ZR24-2 Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 Type: ZR-EXT-01   Pipe connectors for ball valve with internal thread:     DN 15 Rp 1/2" Type: ZR2315     DN 20 Rp 3/4" Type: ZR2320     DN 25 Rp 1" Type: ZR2325     DN 32 Rp 1 1/4" Type: ZR2332     DN 40 Rp 1 1/2" Type: ZR2340     DN 50 Rp 2" Type: ZR2350   Why You Should Buy High Performance: With high close-off and differential pressures, these valves ensure reliable operation even under demanding conditions. Durability: Constructed with nickel-plated brass and stainless steel, these valves offer long-term durability and resistance to wear and corrosion. Ease of Installation and Maintenance: Featuring a simple design with internal threading, these valves are easy to install and require no maintenance, ensuring hassle-free operation. Comprehensive Accessories: A range of accessories is available to enhance functionality and adapt the valve to specific requirements.   Additional Notes Water Quality Requirements: Adhere to VDI 2035 water quality requirements. A suitable strainer should be installed to keep the valves free from particle debris. Servicing: Ensure all electrical connections are isolated and the system is depressurized before servicing. For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £141.00£98.70

  • Belimo R2025-S2 Open/Close 2-Way Ball Valve

    Belimo R2025-S2 Open/Close 2-Way Ball Valve

    For tradesmen and engineering companies seeking reliable and efficient components for their water systems, the Belimo Open/Close Ball Valve R2025-S is an excellent choice. These valves are designed for heating, ventilation, and air-conditioning systems and ensure optimal performance and longevity. Click here for the technical data PDF The Belimo R2025-S2 series valves are designed for open and closed cold and warm water systems. They are ideal for shut-off functions in water systems and provide 2-point controls in air-handling units and heating systems. These valves are air-bubble tight, ensuring no leakage and maintaining system integrity.   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -10°C to 120°C (14°F to 248°F) Note: At fluid temperatures of -10°C to 2°C, a spindle heater or valve neck extension is recommended. The allowed fluid temperature may be limited based on the type of actuator used. Close-off Pressure (Δps): 1400 kPa Differential Pressure (Δpmax): 1000 kPa (200 kPa for low-noise operation) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal (relative to the stem) Servicing: Maintenance-free   Materials: Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Operating Mode: The open/close ball valve is adjusted by a rotary actuator, connected by an open/close signal. Turn the valve counterclockwise to open and clockwise to close. Flow Direction: The direction of flow is indicated by an arrow on the housing, ensuring correct installation and preventing damage. Permissible Installation Orientation: Upright to horizontal. Avoid hanging position (spindle pointing downwards).   Electrical Accessories: Stem heater DN 15...50 (20 W) Type: ZR24-2 Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 Type: ZR-EXT-01   Pipe connectors for ball valve with internal thread:     DN 15 Rp 1/2" Type: ZR2315     DN 20 Rp 3/4" Type: ZR2320     DN 25 Rp 1" Type: ZR2325     DN 32 Rp 1 1/4" Type: ZR2332     DN 40 Rp 1 1/2" Type: ZR2340     DN 50 Rp 2" Type: ZR2350   Why You Should Buy High Performance: With high close-off and differential pressures, these valves ensure reliable operation even under demanding conditions. Durability: Constructed with nickel-plated brass and stainless steel, these valves offer long-term durability and resistance to wear and corrosion. Ease of Installation and Maintenance: Featuring a simple design with internal threading, these valves are easy to install and require no maintenance, ensuring hassle-free operation. Comprehensive Accessories: A range of accessories is available to enhance functionality and adapt the valve to specific requirements.   Additional Notes Water Quality Requirements: Adhere to VDI 2035 water quality requirements. A suitable strainer should be installed to keep the valves free from particle debris. Servicing: Ensure all electrical connections are isolated and the system is depressurized before servicing.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £95.10£66.57

  • Belimo R2025-10-S2 Control Valve

    Belimo R2025-10-S2 Control Valve

    Discover the precision and reliability of the Belimo R2025-10-S2 Characterised Control Valve, designed for optimal performance in open and closed cold and warm water systems. Ideal for modulating control of air-handling and heating systems on the waterside, this valve ensures air-bubble-tight sealing and efficient fluid management.   Click here for the technical data PDF   Functional Data: - Fluid: Cold and warm water, water with glycol up to max. 50% vol. - Fluid Temperature: -10...120°C [14...248°F]   - Note: At fluid temperatures of -10...2°C, a spindle heater or valve neck extension is recommended. Fluid temperature limits may vary based on the actuator type. - Close-off Pressure ∆ps: 1400 kPa - Differential Pressure Δpmax: 350 kPa   - Note: 200 kPa for low-noise operation - Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range - Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) - Angle of Rotation: 90°   - Note: Operating range 15...90° - Pipe Connection: Internal thread according to ISO 7-1 - Installation Orientation: Upright to horizontal (in relation to the stem) - Servicing: Maintenance-free   Material Composition: - Valve Body: Nickel-plated brass - Closing Element: Stainless steel - Spindle: Stainless steel - Spindle Seal: EPDM O-ring - Seat: PTFE, O-ring EPDM - Characterised Disc: ETFE   Product Features: Operating Mode: It is adjusted by a rotary actuator controlled by a commercially available modulating or 3-point control system. The ball of the valve (throttling device) moves to the position dictated by the control signal. - Flow Characteristic: The integrated characterising disc ensures Equal percentage flow control.   Additional Accessories: - Electrical Accessories:   - Stem heater DN 15...50 (20 W) - Type: ZR24-2 - Mechanical Accessories:   - Valve neck extension for ball valve DN 15...50 - Type: ZR-EXT-01   - Pipe connectors for ball valves with internal thread:     - DN 15 Rp 1/2" - Type: ZR2315     - DN 20 Rp 3/4" - Type: ZR2320     - DN 25 Rp 1" - Type: ZR2325     - DN 32 Rp 1 1/4" - Type: ZR2332     - DN 40 Rp 1 1/2" - Type: ZR2340     - DN 50 Rp 2" - Type: ZR2350   Installation Notes: - Permissible Installation Orientation: The ball valve can be installed upright to horizontal, but not in a hanging position (spindle pointing downwards). - Water Quality Requirements: Adhere to VDI 2035. Ensure valves are free from particle debris. Installation of a suitable strainer is recommended.     Why You Should Buy: - Reliability: Designed for robust performance in HVAC systems. - Efficiency: Optimized for low-noise and efficient fluid control. - Durability: Constructed from high-quality materials, ensuring long-lasting operation. - Ease of Installation: Flexible installation orientations and maintenance-free design.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.  

    £104.00£72.80

  • Belimo R2020-S2 Open/Close 2-Way Ball Valve

    Belimo R2020-S2 Open/Close 2-Way Ball Valve

    The Belimo R2020-S2 series open/close ball valve is engineered to precisely control cold and warm water systems, including water with glycol up to a maximum of 50% volume. This valve ensures air-bubble-tight sealing and reliable performance and is ideal for shut-off functions on the waterside and 2-point controls in air-handling units and heating systems.   Click here for the technical data PDF   Open/close ball valve, 2-way, DN 20, Internal thread, Rp 3/4", PN 40, ps 1600 kPa, Kvs 32 m³/h, Fluid temperature -10...120°C [14...248°F]   Product Features Type: 2-way, Internal thread Application: Open and closed cold and warm water systems, shut-off functions, air-handling units, heating systems Operation: Adjusted by a rotary actuator with open/close signal Installation Orientation: Upright to horizontal (in relation to the stem) Maintenance: Maintenance-free   Functional Data Fluid: Cold and warm water, water with glycol (up to 50% vol.) Fluid Temperature: -10 to 120°C (14 to 248°F)   *Note*: At fluid temperatures of -10 to 2°C, a spindle heater or valve neck extension is recommended. Close-off Pressure ∆ps: 1400 kPa Differential Pressure Δpmax: 1000 kPa   *Note*: 200 kPa for low-noise operation Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90°   Materials Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Connections Pipe Connection: Internal thread according to ISO 7-1   Dimensions Dimensional Drawings: Refer to the product datasheet for detailed dimensions   Safety and Compliance Protection Class: IEC/EN Certification: EMC, UL Approval Installation Requirements: Only authorised specialists should install according to applicable regulations. Disposal: Must be disposed of according to local regulations Electrical Accessories:   Stem heater DN 15...50 (20 W) ZR24-2   Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 ZR-EXT-01   Pipe connectors for various DN sizes (15 to 50)   Water Quality Requirements: Must adhere to VDI 2035 standards   Servicing: Maintenance-free; ensure isolation of rotary actuator from the power supply before service   Flow Direction: Must comply with the specified direction of flow marked on the housing to avoid damage   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.  

    £77.20£54.04

  • Belimo R2015-S1 Open/Close 2-Way Ball Valve

    Belimo R2015-S1 Open/Close 2-Way Ball Valve

    Open/close ball valve, 2-way, DN 15, Internal thread, Rp 1/2", PN 40, ps 1600 kPa, Kvs 15 m³/h, Fluid temperature -10...120°C [14...248°F] Click here for the technical data PDF For tradesmen and engineering companies seeking reliable and efficient components for their water systems, the Belimo Open/Close Ball Valve R2015-S1 is an excellent choice. These valves are designed for heating, ventilation, and air-conditioning systems and ensure optimal performance and longevity. The Belimo R2015-S1 series valves are designed for open and closed cold and warm water systems. They are ideal for shut-off functions in water systems and provide 2-point controls in air-handling units and heating systems. These valves are air-bubble tight, ensuring no leakage and maintaining system integrity.   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -10°C to 120°C (14°F to 248°F) Note: At fluid temperatures of -10°C to 2°C, a spindle heater or valve neck extension is recommended. The allowed fluid temperature may be limited based on the type of actuator used. Close-off Pressure (Δps): 1400 kPa Differential Pressure (Δpmax): 1000 kPa (200 kPa for low-noise operation) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal (relative to the stem) Servicing: Maintenance-free   Materials: Valve Body: Nickel-plated brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM   Operating Mode: The open/close ball valve is adjusted by a rotary actuator, connected by an open/close signal. Turn the valve counterclockwise to open and clockwise to close. Flow Direction: The direction of flow is indicated by an arrow on the housing, ensuring correct installation and preventing damage. Permissible Installation Orientation: Upright to horizontal. Avoid hanging position (spindle pointing downwards).   Electrical Accessories: Stem heater DN 15...50 (20 W) Type: ZR24-2 Mechanical Accessories:   Valve neck extension for ball valve DN 15...50 Type: ZR-EXT-01   Pipe connectors for ball valve with internal thread:     DN 15 Rp 1/2" Type: ZR2315     DN 20 Rp 3/4" Type: ZR2320     DN 25 Rp 1" Type: ZR2325     DN 32 Rp 1 1/4" Type: ZR2332     DN 40 Rp 1 1/2" Type: ZR2340     DN 50 Rp 2" Type: ZR2350   Why You Should Buy High Performance: With high close-off and differential pressures, these valves ensure reliable operation even under demanding conditions. Durability: Constructed with nickel-plated brass and stainless steel, these valves offer long-term durability and resistance to wear and corrosion. Ease of Installation and Maintenance: Featuring a simple design with internal threading, these valves are easy to install and require no maintenance, ensuring hassle-free operation. Comprehensive Accessories: A range of accessories is available to enhance functionality and adapt the valve to specific requirements.   Additional Notes Water Quality Requirements: Adhere to VDI 2035 water quality requirements. A suitable strainer should be installed to keep the valves free from particle debris. Servicing: Ensure all electrical connections are isolated and the system is depressurized before servicing.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.

    £69.30£48.51

  • Belimo EP015R2+BAC control valve

    Belimo EP015R2+BAC control valve

    Enhance the performance and reliability of your HVAC system with the Belimo EP015R2+BAC Control Valve. Designed for precise control in closed cold and warm water systems, this valve ensures efficient operation in air-handling and heating systems.   Click here for the technical data PDF     NOTE: The accessory EXT-EF-F (pipe connector) is required for installation in the pipe. Please include in your order! See below in "Mechanical accessories"   Mechanical accessories: Pipe connector DN 15 Rp 1/2", G 3/4" - EXT-EF-15F Pipe connector DN 20 Rp 3/4", G 1"  - EXT-EF-20F Pipe connector DN 25 Rp 1", G 1 1/4"  - EXT-EF-25F Pipe connector DN 32 Rp 1 1/4", G 1 1/2"  - EXT-EF-32F Pipe connector DN 40 Rp 1 1/2", G 2"  - EXT-EF-40F Pipe connector DN 50 Rp 2", G 2 1/2"  - EXT-EF-50F   Electrical Data: Nominal Voltage: AC/DC 24 V Nominal Voltage Frequency: 50/60 Hz Nominal Voltage Range: AC 19.2...28.8 V / DC 21.6...28.8 V Power Consumption in Operation: 4 W (DN 15, 20, 25); 5 W (DN 32, 40, 50) Power Consumption in Rest Position: 3.7 W (DN 15, 20, 25); 3.9 W (DN 32, 40, 50) Power Consumption for Wire Sizing: 6.5 VA (DN 15, 20, 25); 7.5 VA (DN 32, 40, 50) Connection Supply / Control: Cable 1 m, 6x 0.75 mm²   Functional Data: Operating Range Y: 2...10 V Operating Range Y Variable: 0.5...10 V Position Feedback U: 2...10 V Position Feedback U Note: Max. 1 mA Sound Power Level Motor: 35 dB(A) (DN 15, 20, 25, 32, 40); 45 dB(A) (DN 50) V'max Adjustable: 25...100% of V'nom Control Accuracy: ±5% (of 25...100% V'nom) Control Accuracy Note: ±10% (of 25...100% V'nom) @ Glycol 0...60% vol. Min. Controllable Flow: 1% of V'nom Parametrisation: Via NFC, Belimo Assistant App Fluid: Cold and warm water, water with glycol up to max. 60% vol. Fluid Temperature: -10...120°C [14...248°F] Close-Off Pressure Δps: 1400 kPa Differential Pressure Δpmax: 350 kPa Differential Pressure Note: 200 kPa for low-noise operation Flow Characteristic: Equal percentage, optimised in the opening range (switchable to linear) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Pipe Connection: Internal and external thread Installation Orientation: Upright to horizontal (in relation to the stem) Servicing: Maintenance-free Manual Override: With push-button, can be locked   Measuring Data: Measured Values: Flow, fluid temperature in valve unit Temperature Sensor: Pt1000 EN 60751, 2-wire technology, integrated in flow sensor Temperature Measurement Accuracy: ±0.35°C @ 10°C (Pt1000 EN60751 Class B); ±0.6°C @ 60°C (Pt1000 EN60751 Class B) Flow Measurement Principle: Ultrasonic volumetric flow measurement Flow Measurement Accuracy: ±2% (of 20...100% V'nom) @ 20°C / glycol 0% vol.; ±5% (of 20...100% V'nom) @ glycol 0...60% vol. Min. Flow Measurement: 0.5% of V'nom Glycol Monitoring: Measurement display glycol 0...60% or >60%; accuracy ±4% (0...60%)   Safety Data: Protection Class IEC/EN: III, Protective Extra-Low Voltage (PELV) Degree of Protection IEC/EN: IP54 Pressure Equipment Directive: CE according to 2014/68/EU EMC: CE according to 2014/30/EU Certification IEC/EN: IEC/EN 60730-1:11 and IEC/EN 60730-2-15:10 Quality Standard: ISO 9001 Type of Action: Type 1 Rated Impulse Voltage Supply / Control: 0.8 kV Pollution Degree: 3 Ambient Humidity Max.: 95% RH, non-condensing Ambient Temperature: -30...50°C [-22...122°F] Storage Temperature: -40...80°C [-40...176°F]   Materials: Valve Body: Brass Flow Measuring Pipe: Brass body nickel-plated Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring     Installation Notes: The ball valve can be installed upright to horizontal but not in a hanging position. Installation in the return is recommended to maintain accuracy. Adhere to VDI 2035 water quality requirements for long-term functionality. Suitable strainers should be installed to prevent particle debris. Split installation is possible with observance of the direction of flow for both components.   Operating Mode: The HVAC performance device is comprised of three components: characterised control valve (CCV), measuring pipe with flow sensor, and the actuator itself. The adjusted maximum flow (V'max) is assigned to the maximum control signal (typically 100%). The device can be controlled via communicative signals. The fluid is detected by the sensor in the measuring pipe and applied as the flow value. The measured value is balanced with the setpoint, and the actuator corrects the deviation by changing the valve position. The angle of rotation varies according to the differential pressure through the control element.   Calibration Certificate: Available in the Belimo Cloud for each device. It can be downloaded as a PDF through the Belimo Assistant App.   Control Characteristics: The fluid velocity is measured in the measuring component and converted to a flow rate signal. The control signal corresponds to the power via the exchanger, regulating the flow in the EPIV. The control signal is converted into an equal-percentage characteristic curve and provided with the V'max value as the new reference variable. The momentary control deviation forms the control signal for the actuator. The precise flow sensor ensures stable control quality, although it is not suitable for rapid control processes like domestic water control.   Fluid Temperature Measurement: The temperature sensor integrated into the flow sensor permanently measures the medium temperature. The measured value can be read via the bus system or the analogue feedback signal. The current measured value is also displayed in the Belimo Assistant App.   Creep Flow Suppression: Electronically overrides the very low flow speed in the opening point that the sensor cannot measure within the required tolerance.   Converter for Sensors: Connection option for a sensor (active or with switching contact), allowing the analogue sensor signal to be digitised and transferred to the bus systems BACnet, Modbus, or MP-Bus.   Control Signal Inversion: Inverts the control signal in cases where the standard behaviour needs reversing. For example, at a control signal of 0%, regulation is to V'max, and the valve is closed at a control signal of 100%.   Hydronic Balancing: Maximum flow rate can be adjusted on-site with Belimo tools. If integrated into the management system, balancing can be handled directly by the system.   Combination Analogue-Communicative (Hybrid Mode): Uses conventional control by an analogue control signal with communicative position feedback via BACnet, Modbus, or MP-Bus.   Glycol Monitoring: Measures the actual glycol content to ensure safe operation and optimised heat exchange.   Error Readout with Analogue Position Feedback: Indicates sensor errors by 0.3 V at the position feedback U, only if the feedback U is set to flow and the lower value of the signal range is 0.5 V or more.   High Functional Safety: The actuator is overload protected, requires no limit switches, and automatically stops when the end stop is reached.     Safety Notes: The device is designed for use in stationary heating, ventilation, and air-conditioning systems and must not be used outside the specified field of application, such as in aircraft or any airborne means of transport. Outdoor application is only possible if conditions such as no (sea) water, snow, ice, insolation, or aggressive gases interfering directly with the device are met, and ambient conditions remain within the specified thresholds.   Installation notes:   Flow Direction: The direction of flow, specified by an arrow on the housing, must be complied with to ensure correct flow rate measurement.   Inlet Section: A flow-calming section or inflow section in the direction of the flow must be provided upstream from the flow sensor to achieve the specified measuring accuracy. The dimensions should be at least 5x DN.   Split Installation: The valve-actuator combination may be mounted separately from the flow sensor, with observance of the direction of flow for both components.   Minimum Differential Pressure: The minimum required differential pressure for achieving the desired volumetric flow V'max can be calculated with the theoretical kvs value and the desired maximum flow rate.   Behaviour in Case of Sensor Failure: In case of a flow sensor error, the EPIV will switch from flow control to position control. Once the error disappears, the EPIV will switch back to the normal control setting.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please contact us.

    £552.00£386.40

  • Belimo D665N Butterfly Valve (DN65)

    Belimo D665N Butterfly Valve (DN65)

    The Belimo D6..N series butterfly valves are essential components in various industrial applications, and they are known for their cost-effectiveness, lightweight design, and efficient flow regulation. These quarter-turn rotational motion valves are ideal for controlling the flow through pipelines by quickly opening or closing with a simple 90-degree rotation. Widely used in pharmaceutical, chemical, and food industries, as well as in water flow control for dams and hydroelectric power plants, butterfly valves offer both control and protection functions. Their versatility and reliability make them a preferred choice for managing flow in numerous applications, ensuring optimal performance and safety.   Click here for the technical data PDF    Type Overview - D625N: DN 25, Kvmax 50 m³/h, Kvs 24 m³/h, PN 6/10/16, n(gl) 3.2 - D632N: DN 32, Kvmax 55 m³/h, Kvs 25 m³/h, PN 6/10/16, n(gl) 3.2 - D640N: DN 40, Kvmax 65 m³/h, Kvs 27 m³/h, PN 6/10/16, n(gl) 3.2 - D650N: DN 50, Kvmax 100 m³/h, Kvs 30 m³/h, PN 6/10/16, n(gl) 3.2 - D665N: DN 65, Kvmax 170 m³/h, Kvs 50 m³/h, PN 6/10/16, n(gl) 3.2 - D680N: DN 80, Kvmax 260 m³/h, Kvs 75 m³/h, PN 6/10/16, n(gl) 3.2 - D6100N: DN 100, Kvmax 520 m³/h, Kvs 150 m³/h, PN 6/10/16, n(gl) 3.2 - D6125N: DN 125, Kvmax 880 m³/h, Kvs 260 m³/h, PN 6/10/16, n(gl) 3.2 - D6150N: DN 150, Kvmax 1400 m³/h, Kvs 400 m³/h, PN 6/10/16, n(gl) 3.2 - D6350N: DN 350, Kvmax 10300 m³/h, Kvs 3010 m³/h, PN 10/16, n(gl) 3.2 - D6400N: DN 400, Kvmax 14200 m³/h, Kvs 4140 m³/h, PN 16, n(gl) 3.2 - D6450N: DN 450, Kvmax 18800 m³/h, Kvs 5490 m³/h, PN 16, n(gl) 3.2 - D6500N: DN 500, Kvmax 24100 m³/h, Kvs 7060 m³/h, PN 16, n(gl) 3.2 - D6600N: DN 600, Kvmax 37300 m³/h, Kvs 10900 m³/h, PN 16, n(gl) 3.2 - D6700N: DN 700, Kvmax 42800 m³/h, Kvs 11760 m³/h, PN 16, n(gl) 3.2   The types D6200N, D6250N, and D6300N have been replaced by D6200W, D6250W, and D6300W respectively.      Functional Data - Fluid: Cold and warm water, water with glycol up to max. 50% vol. - Fluid Temperature: -10...120°C [14...248°F] - Flow Characteristic:   - 0...60% opening angle: equal percentage (VDI/VDE 2173)   - 0...100% opening angle: S-form - Leakage Rate: Tight, leakage rate A (EN 12266-1) - Angle of Rotation: 90° - Pipe Connection: Flange according to ISO 7005-2, EN 1092-2, PN6/10/16, AS Table E (DN 50...150), PN10/16, AS Table E (DN 350), PN16 (DN 400...600) - Installation Orientation: Upright to horizontal (in relation to the stem) - Servicing: Maintenance-free   Materials - Valve Body: EN-GJS-400-15 (GGG 40) - Body Finish: Polyester powder coated - Closing Element: Stainless steel AISI 304 (1.4301) - Spindle:   - Stainless steel AISI 420 (1.4021) (DN 25, 32, 40, 50, 65, 80, 100, 125, 150)   - Stainless steel AISI 630 (1.4542) (DN 350, 400, 450, 500, 600, 700) - Spindle Seal: EPDM O-ring - Spindle Bearing: RPTFE - Seat: EPDM   Operating Mode The butterfly valve is opened or closed completely by an open/close rotary actuator. A commercially available controller connects continuous rotary actuators and move the valve to any desired position. The valve disk made of stainless steel is pressed into the soft-sealing EPDM seat by a rotary movement, ensuring a tight seal with minimal pressure loss when open, maximising the Kv value.   Manual Override - Manual Throttling/Isolation: With lever or worm gear (see accessories)   - With lever (DN 25…150): Adjustable in 10 ratchet steps with position indication (0 = 0°; 9 = 90°)   - With worm gear (DN 25...700): Steplessly adjustable (self-locking) with position indication   Accessories - Electrical: Stem heater flange F05 (30 W) ZR24-F05 - Mechanical:   - Worm gear for butterfly valves DN 25...100 ZD6N-S100   - Lever for butterfly valves DN 25...100 ZD6N-H100   - Worm gear for butterfly valves DN 125...300 ZD6N-S150   - Lever for butterfly valves DN 125...150 ZD6N-H150   - Worm gear for butterfly valves DN 350 ZD6N-S350   - Worm gear for butterfly valves DN 400 ZD6N-S400   - Worm gear for butterfly valves DN 450 ZD6N-S450   - Worm gear for butterfly valves DN 500 ZD6N-S500   - Worm gear for butterfly valves DN 600 ZD6N-S600   - Worm gear for butterfly valves DN 700 ZD6N-S700    Flow Setting - Characteristic Curve: Equal percentage characteristic curve between 0...60% opening angle. Linear characteristic curve can be set using the Belimo Assistant App.   Dimensions Refer to the dimensional drawings for precise measurements in the included images.   For more information and to explore our range of Belimo products, visit our website at [ecospares.co.uk/collections/belimo](https://ecospares.co.uk/collections/belimo). If you need any assistance, please get in touch with us on 01772 284 626.  

    £172.00£120.40

  • Belimo C420Q-K Zone Valve

    Belimo C420Q-K Zone Valve

    Zone valve, 2-way, DN 20, External thread, G 3/4", PN 25, ps 1600 kPa, Kvs 7.8 m³/h, Fluid temperature 2...100°C [36...212°F] (with actuator 2...90°C) The Belimo Zone Valve C420Q-K is an advanced, high-performance valve designed for closed cold and warm water systems, ideal for shut-off functions and modulating controls in air-handling units and heating systems. Featuring a tool-free snap-assembly actuator and adjustable kvs values, this valve ensures precision and reliability in various HVAC applications.   Click here for the technical data PDF   Included Parts and Accessories Standard Package:   Valve body   Rotary actuator (specific model based on control requirements) Optional Accessories:   Spindle extension (Type: ZCQ-E)   Pipe connectors for DN15 (Rp 1/2") and DN20 (Rp 3/4") ball valves   Functional Data: Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: 2...100°C [36...212°F] with actuator: 2...90°C Close-off Pressure (∆ps): 520 kPa Differential Pressure (Δpmax): 280 kPa (50 kPa for low-noise operation) Flow Characteristic: Equal percentage (VDI/VDE 2173), optimised in the opening range Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Flow Setting: Adjustable in 2.5° increments Angle of Rotation: 90° (Operating range 15...90°) Pipe Connection: External thread according to ISO 228-1 Installation Orientation: Upright to horizontal (in relation to the stem) Servicing: Maintenance-free   Materials: Valve Body: Brass Closing Element: Chrome-plated brass Spindle: Brass Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM     Safety and Compliance: Protection Class (IEC/EN): Rated according to specific actuator used Degree of Protection (NEMA/UL): Rated according to specific actuator used Certification: Compliance with EMC and other relevant standards   Operating Mode: The ball valve is adjusted by a rotary actuator, controlled by an open/close signal or a modulating control system.   Simple Direct Mounting: Tool-free snap assembly for quick and easy installation. Flow Direction: Can operate in both flow directions.   Flow Setting Adjustability: Angle of rotation can be adjusted to set the kvs value, ensuring optimal flow rates.   Maintenance-Free Design: Engineered for long-term reliability with no maintenance required.     Installation Notes Orientation: Install upright to horizontal. Avoid hanging positions. Water Quality: Adhere to VDI 2035 water quality requirements to prevent particle debris. Flow Setting: Adjust kvs value by modifying the actuator's angle of rotation. Trigger adaptation on modulating actuators after changes.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please get in touch with us on 01772 284 626.  

    £45.70£31.99

  • Belimo C220QP-F zone valve

    Belimo C220QP-F zone valve

    Optimised for Modulating Control of Air-Handling and Heating Systems   Introducing the Belimo PI Zone Valve, a state-of-the-art solution designed for closed cold and warm water systems, ensuring efficient and precise modulating control of air-handling and heating systems on the water side. With robust construction and advanced features, this valve is perfect for tradesmen and engineering companies looking for reliable and durable components.   Click here for the technical data PDF   Snap-Assembly of the Actuator: Quick and easy installation with snap-assembly.   Equal Percentage Flow Control: Ensured by the special design of the ball for optimal performance.   Integrated Pressure Regulating Valve: Achieves constant flow volume regardless of differential pressure.   Measuring Ports: Equipped with P/T ports to easily determine pressure drops and ensure accurate flow rate.       Technical Specifications Fluid: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature: -20...120°C [-4.0...248°F] Differential Pressure: 16...350 kPa Close-off Pressure: 1400 kPa Flow Characteristic: Equal percentage (VDI/VDE 2173), optimised in the opening range Pressure Stability: ±5% (35...350 kPa), ±10% (16...35 kPa) Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° (Operating range 15...90°) Pipe Connection: Internal thread according to ISO 7-1 Installation Orientation: Upright to horizontal Servicing: Maintenance-free   Materials Valve Body: Brass Closing Element: Stainless steel Spindle: Stainless steel Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM Diaphragm: EPDM   Accessories Spindle Extension: CQ ZCQ-E Flow Limiter: PIQCV ZCQ-FL Pipe Connectors:   DN 15 Rp 1/2" (ZR2315)   DN 20 Rp 3/4" (ZR2320)   DN 25 Rp 1" (ZR2325)     Why You Should Buy   The Belimo PI Zone Valve is a top-tier choice for anyone needing a reliable and efficient valve for modulating control in air-handling and heating systems. Its advanced features, such as the integrated pressure regulating valve and equal percentage flow control, ensure consistent performance and long-term durability. With a range of sizes and accessories available, this valve meets the diverse needs of tradesmen and engineering companies.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.    

    £174.00£121.80

  • Belimo C215QPT-B (2-way) PI Zone Valve

    Belimo C215QPT-B (2-way) PI Zone Valve

    The Belimo PI Zone Valve, 2-way with internal thread, is engineered for closed cold and warm water systems. It delivers precise control for air handling and heating systems. Ideal for tradespeople and engineering companies, this valve ensures optimal performance and reliability.   - Functional Data:   - Fluid: Cold and warm water with glycol up to max. 50% vol.   - Fluid Temperature: -20...120°C [-4.0...248°F]   - Differential Pressure: 16...350 kPa   - Close-off Pressure: ∆ps 1400 kPa   - Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range   - Pressure Stability: ±5% (35...350 kPa), ±10% (16...35 kPa)   - Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1)   - Angle of Rotation: 90° (Operating range 15...90°)   - Pipe Connection: Internal thread according to ISO 7-1   - Installation Orientation: Upright to horizontal (in relation to the stem)   - Servicing: Maintenance-free   - Material Composition:   - Valve Body: Brass   - Closing Element: Stainless steel   - Spindle: Stainless steel   - Spindle Seal: EPDM O-ring   - Seat: PTFE, O-ring EPDM   - Diaphragm: EPDM       Operating Mode: The ball valve is adjusted by a rotary actuator, controlled by a modulating or 3-point control system.   Flow Characteristic: Equal percentage flow control is ensured by the special design of the ball.   Constant Flow Volume: Maintains a constant flow volume with a differential pressure of 16…350 kPa.   Measuring Ports (P/T Ports): These are included in C2..QPT-.. types for easy pressure differential measurement.   Installation Orientation: Permissible upright to horizontal installation. Not suitable for hanging installation.   Servicing: Maintenance-free ball valves and rotary actuators. Before any service work, ensure the rotary actuator is isolated from the power supply.       - Mechanical Accessories:   - Spindle Extension: CQ ZCQ-E   - Flow Limiter: PIQCV ZCQ-FL   - Pipe Connector: Available for DN 15, DN 20, and DN 25 with respective internal threads.     Why You Should Buy: - Precision Control: Optimized for modulating control in HVAC systems. - Durability: Made with high-quality materials like brass and stainless steel for long-lasting performance. - Easy Maintenance: Designed to be maintenance-free, reducing downtime and service costs. - Versatility: Suitable for a wide range of applications in heating and cooling systems.       For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please call us on 01772 284 626.  

    £169.00£118.30

  • Belimo C215QP-D two-way zone valve

    Belimo C215QP-D two-way zone valve

    PI Zone Valve (PIQCV), 2-way, DN 15, Internal thread, Rp 1/2", PN 25, ps 1600 kPa, V'nom 420 l/h, Fluid temperature -20...120°C [-4...248°F] (with actuator 2...90°C) Click here for the technical data PDF Belimo PI Zone Valve, 2Way, Internal Thread The Belimo PI Zone Valve is an advanced solution designed for modulating control of airhandling and heating systems on the water side, ideal for use in closed cold and warm water systems. Its snapassembly actuator ensures ease of installation and reliable operation. Explore our comprehensive range here on ECO SPARES  Product Overview  Type Overview:    C215QPB: DN 15, Rp 1/2, Nominal Flow 0.058 l/s, 210 l/h, 0.21 m³/h    C215QPD: DN 15, Rp 1/2, Nominal Flow 0.117 l/s, 420 l/h, 0.42 m³/h    C215QPTB: DN 15, Rp 1/2, Nominal Flow 0.058 l/s, 210 l/h, 0.21 m³/h    C215QPTD: DN 15, Rp 1/2, Nominal Flow 0.117 l/s, 420 l/h, 0.42 m³/h    C220QPF: DN 20, Rp 3/4, Nominal Flow 0.272 l/s, 980 l/h, 0.98 m³/h    C220QPTF: DN 20, Rp 3/4, Nominal Flow 0.272 l/s, 980 l/h, 0.98 m³/h    C225QPTG: DN 25, Rp 1, Nominal Flow 0.583 l/s, 2100 l/h, 2.1 m³/h    PT = Version with measuring ports (P/T ports)   Technical Specifications Functional Data  Fluid: Cold and warm water, water with glycol up to max. 50% vol.  Fluid Temperature: 20...120°C [4.0...248°F], with actuator 2...90°C  Differential Pressure: 16...350 kPa  Closeoff Pressure: ∆ps 1400 kPa  Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range  Pressure Stability: ±5% with a pressure value of 35...350 kPa, ±10% with a pressure   value of 16...35 kPa  Leakage Rate: Airbubble tight, leakage rate A (EN 122661)  Angle of Rotation: 90°, Operating range 15...90°  Pipe Connection: Internal thread according to ISO 71  Installation Orientation: Upright to horizontal (in relation to the stem)  Servicing: Maintenance free   Materials  Valve Body: Brass  Closing Element: Stainless steel  Spindle: Stainless steel  Spindle Seal: EPDM Oring  Seat: PTFE, Oring EPDM  Diaphragm: EPDM   Safety Notes  Designed for use in stationary heating, ventilation, and air conditioning systems.  Only authorised specialists may carry out installation.  Must not be used outside the specified field of application.  Disposal must follow local regulations.   Product Features Operating Mode: Adjusted by a rotary actuator, controlled by a commercially available modulating or 3 point control system. Flow Characteristic: Equal percentage flow control ensured by the special design of the ball. Constant Flow Volume: Achieved with a differential pressure of 16…350 kPa. Measuring Ports (P/T Ports): Available in C2..QPT.. type valves for differential pressure measurement and optimization.   Installation Notes Permissible installation orientation is upright to horizontal, not hanging. Installation in the return is recommended. Adhere to VDI 2035 water quality requirements. Keep valves free from particle debris; installation of a suitable strainer is recommended. Ensure flow direction as specified by the arrow on the housing.   Accessories  Spindle Extension: CQ ZCQE  Flow Limiter: PIQCV ZCQFL  Pipe Connector:   DN 15 Rp 1/2" ZR2315   DN 20 Rp 3/4" ZR2320   DN 25 Rp 1" ZR2325   For more details and to view our entire range, please visit (http://www.ecospares.co.uk). If you need assistance, feel free to get in touch with us.

    £139.00£97.30

  • Belimo C215Q-F Zone valve (2-way)

    Belimo C215Q-F Zone valve (2-way)

    Zone valve, 2-way, DN 15, Internal thread, Rp 1/2", PN 25, ps 1600 kPa, Kvs 4.8 m³/h, Fluid temperature 2...100°C [36...212°F] (with actuator 2...90°C) Click here for the technical data PDF The Belimo C215Q-F 2-way zone valve is expertly designed for closed cold and warm water systems. Ideal for shut-off functions and modulating controls on the water side of air-handling units and heating systems, this series offers reliable performance and ease of use. These valves ensure efficient and precise fluid flow control with snap-assembly actuators and various technical specifications. Functional Data Fluid Compatibility: Cold and warm water, water with glycol up to max. 50% vol. Fluid Temperature Range: 2...100°C (with actuator 2...90°C) Close-off Pressure (∆ps): 520 kPa Differential Pressure (Δpmax): 280 kPa Flow Characteristic: Equal percentage (VDI/VDE 2173), optimized in the opening range Leakage Rate: Air-bubble tight, leakage rate A (EN 12266-1) Angle of Rotation: 90° (Operating range 15...90°) Installation Orientation: Upright to horizontal   Mechanical Data Valve Body Material: Brass Closing Element: Chrome-plated brass Spindle: Brass Spindle Seal: EPDM O-ring Seat: PTFE, O-ring EPDM Pipe Connection: Internal thread according to ISO 7-1   Snap-Assembly Actuator: Tool-free snap assembly for quick and easy installation. Flow Setting: Adjustable angle of rotation in 2.5° increments for precise flow control. Maintenance-Free: Both ball valves and rotary actuators require no maintenance. Flow Direction: Bidirectional flow capability.   Accessories Spindle Extension (CQ ZCQ-E) Pipe Connectors:   DN 15 Rp 1/2" (ZR2315)   DN 20 Rp 3/4" (ZR2320)   DN 25 Rp 1" (ZR2325)   Installation Notes Permissible Orientation: Must not be installed in a hanging position. Water Quality Requirements: Adherence to VDI 2035 for long-term functionality. Servicing: Isolate the rotary actuator from the power supply before any service work. Ensure all components are cooled down, and system pressure is reduced to ambient level.   Certification and Compliance Safety: Designed for stationary heating, ventilation, and air-conditioning systems. EMC and Certification: Conforms to relevant standards, ensuring safe and reliable operation. Belimo's C215Q-F zone valve offers superior control and reliability for your HVAC systems. Focusing on ease of installation, maintenance-free operation, and precision control, these valves are the ideal choice for professional tradesmen and engineering companies.   For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please contact us on 01772 284 626.