Belimo 01DT-1NN duct/immersion temperature sensor

Description

The Belimo 01DT-1N is a versatile duct/immersion temperature sensor designed for accurate temperature measurement in HVAC applications. It can be used in both air ducts and pipe applications when paired with a suitable thermowell. The sensor is housed in an IP65/NEMA 4X rated enclosure, ensuring durability and protection against dust and water ingress.

 

Click here for the technical data PDF

 

Type:  01DT-1NN

Output signal: NTC10k Carel

Probe length:  50 mm

Probe diameter:  6 mm

 

Parts Included:

Mounting Clip: A-22D-A11, with screws and adhesive foil

 

 

Electrical Data:

  • Electrical Connection: Pluggable spring-loaded terminal block, max. 2.5 mm²
  • Cable Entry: Cable gland with strain relief, ø6...8 mm

 

Functional Data:

  • Application: Suitable for air and water
  • Output Signal: Passive temperature NTC10k Carel

 

Measuring Data:

  • Measured Values: Temperature
  • Temperature Measuring Range: -50...150°C (-60...300°F)
  • Measuring Current: <0.2 mA at 25°C (77°F)
  • Accuracy Temperature Passive: ±0.26°C at 25°C (±0.48°F at 77°F)
  • Time Constant τ (63%):
    • -   In water pipe with thermowell brass: Typical 7 s
    • -   With thermowell stainless steel: Typical 9 s
    • -   In air duct at 0 m/s: Typical 210 s
    • -   In air duct at 3 m/s: Typical 46 s

 

Safety Data:

  • Protection Class IEC/EN: III, Protective Extra-Low Voltage (PELV)
  • Power Source UL: Class 2 Supply
  • Degree of Protection IEC/EN: IP65
  • Degree of Protection NEMA/UL: NEMA 4X
  • EU Conformity: CE Marking
  • Certification IEC/EN: IEC/EN 60730-1
  • Quality Standard: ISO 9001
  • UL Approval: cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1/-2-9
  • Type of Action: Type 1
  • Rated Impulse Voltage Supply: 0.8 kV
  • Pollution Degree: 3
  • Ambient Humidity: Max. 95% RH, non-condensing
  • Ambient Temperature: -35...50°C (-30...122°F)
  • Fluid Temperature: -50...150°C (-60...300°F)
  • Housing Surface Temperature: Max. 90°C (195°F)

 

Materials:

  • Cable Gland Plug Adapter: PA66, black
  • Nut: PA6, black
  • Housing Cover and Bottom: PC, orange
  • Seal: NBR70, black
  • Probe Material: V4A (1.4404)

 

Optional Accessories:

  • Mounting Plate S Housing: A-22D-A09
  • Connection Adapter Flex Conduit: M20x1.5, for cable gland 1x 6 mm, Multipack 10 pcs. A-22G-A01.1

Optional Accessories for Air:

  • Mounting Flange for Sensor Probe:
    • 6 mm, up to max. 120°C (248°F), Plastic A-22D-A03
    • 6 mm, up to max. 260°C, Brass A-22D-A05

 

Recommended Accessories for Water:

  • Thermowell Stainless Steel:
    •   150 mm, G 1/2", SW27 A-22P-A10
    •   100 mm, G 1/2", SW27 A-22P-A08
  • Thermowell Brass:
    •   150 mm, R 1/2", SW22 A-22P-A22
    •   100 mm, R 1/2", SW22 A-22P-A20
  • Syringe with Thermal Paste: A-22P-A44
  • Compression Fitting: Stainless steel, G 1/4" (external thread) for 6 mm, with cutting ring A-22P-A45
  • Cold Barrier: Plastic, L 50 mm, for thermowell A-22P-A.. A-22P-A51
  • Adapter for Siemens Thermowell: A-22P-A53

 

For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please contact us.

Product form

The Belimo 01DT-1N is a versatile duct/immersion temperature sensor designed for accurate temperature measurement in HVAC applications. It can be... Read more

SKU: 01DT-1NN
Barcode: 07630498100499

£40.60£28.42 Excl. VAT £34.10 Incl. VAT

  • Fast UK Shipping
  • Genuine manufacturer parts
  • Looking for an out-of-stock item? 📞 Call us at 01772 284 626

    • Shipped today? Order within: Apr 03, 2025 14:00:00 +0100
    • Guaranteed secure & safe checkout.

      shop pay

    Description

    The Belimo 01DT-1N is a versatile duct/immersion temperature sensor designed for accurate temperature measurement in HVAC applications. It can be used in both air ducts and pipe applications when paired with a suitable thermowell. The sensor is housed in an IP65/NEMA 4X rated enclosure, ensuring durability and protection against dust and water ingress.

     

    Click here for the technical data PDF

     

    Type:  01DT-1NN

    Output signal: NTC10k Carel

    Probe length:  50 mm

    Probe diameter:  6 mm

     

    Parts Included:

    Mounting Clip: A-22D-A11, with screws and adhesive foil

     

     

    Electrical Data:

    • Electrical Connection: Pluggable spring-loaded terminal block, max. 2.5 mm²
    • Cable Entry: Cable gland with strain relief, ø6...8 mm

     

    Functional Data:

    • Application: Suitable for air and water
    • Output Signal: Passive temperature NTC10k Carel

     

    Measuring Data:

    • Measured Values: Temperature
    • Temperature Measuring Range: -50...150°C (-60...300°F)
    • Measuring Current: <0.2 mA at 25°C (77°F)
    • Accuracy Temperature Passive: ±0.26°C at 25°C (±0.48°F at 77°F)
    • Time Constant τ (63%):
      • -   In water pipe with thermowell brass: Typical 7 s
      • -   With thermowell stainless steel: Typical 9 s
      • -   In air duct at 0 m/s: Typical 210 s
      • -   In air duct at 3 m/s: Typical 46 s

     

    Safety Data:

    • Protection Class IEC/EN: III, Protective Extra-Low Voltage (PELV)
    • Power Source UL: Class 2 Supply
    • Degree of Protection IEC/EN: IP65
    • Degree of Protection NEMA/UL: NEMA 4X
    • EU Conformity: CE Marking
    • Certification IEC/EN: IEC/EN 60730-1
    • Quality Standard: ISO 9001
    • UL Approval: cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1/-2-9
    • Type of Action: Type 1
    • Rated Impulse Voltage Supply: 0.8 kV
    • Pollution Degree: 3
    • Ambient Humidity: Max. 95% RH, non-condensing
    • Ambient Temperature: -35...50°C (-30...122°F)
    • Fluid Temperature: -50...150°C (-60...300°F)
    • Housing Surface Temperature: Max. 90°C (195°F)

     

    Materials:

    • Cable Gland Plug Adapter: PA66, black
    • Nut: PA6, black
    • Housing Cover and Bottom: PC, orange
    • Seal: NBR70, black
    • Probe Material: V4A (1.4404)

     

    Optional Accessories:

    • Mounting Plate S Housing: A-22D-A09
    • Connection Adapter Flex Conduit: M20x1.5, for cable gland 1x 6 mm, Multipack 10 pcs. A-22G-A01.1

    Optional Accessories for Air:

    • Mounting Flange for Sensor Probe:
      • 6 mm, up to max. 120°C (248°F), Plastic A-22D-A03
      • 6 mm, up to max. 260°C, Brass A-22D-A05

     

    Recommended Accessories for Water:

    • Thermowell Stainless Steel:
      •   150 mm, G 1/2", SW27 A-22P-A10
      •   100 mm, G 1/2", SW27 A-22P-A08
    • Thermowell Brass:
      •   150 mm, R 1/2", SW22 A-22P-A22
      •   100 mm, R 1/2", SW22 A-22P-A20
    • Syringe with Thermal Paste: A-22P-A44
    • Compression Fitting: Stainless steel, G 1/4" (external thread) for 6 mm, with cutting ring A-22P-A45
    • Cold Barrier: Plastic, L 50 mm, for thermowell A-22P-A.. A-22P-A51
    • Adapter for Siemens Thermowell: A-22P-A53

     

    For more information and to explore our range of Belimo products, visit our website at https://ecospares.co.uk/collections/belimo. If you need any assistance, please contact us.

    Recently viewed products

    © 2025 ECO SPARES, Powered by Shopify

      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account